WAGNER FORCE TEN Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Messen, Testen & Steuern WAGNER FORCE TEN herunter. WAGNER FORCE TEN Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 30
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1
OPERATION
MANUAL
The unique Force Five™
featuring interchangeable
Force Cell Modules.
One Gage
Five Capacities!
To change the
capacity simply
change the
Force Cell Module.
FORCE FIVE™
A full feature
digital force
gage with
unprecedented
flexibility at an
economical
price
FORCE FIVE
FORCE GAGE
MULTI-CAPACITY
PATENTED MODULAR DESIGN!
Seitenansicht 0
1 2 3 4 5 6 ... 29 30

Inhaltsverzeichnis

Seite 1 - FORCE GAGE

1OPERATIONMANUALThe unique Force Five™featuring interchangeableForce Cell Modules.One GageFive Capacities!To change thecapacity simplychange theForce

Seite 2 - IMPORTANT

10E. OPERATING INSTRUCTIONSThe following instructions cover the basic operation of the FDVDigital Force Gage, allowing immediate use.1. To turn the F

Seite 3 - OPERATION MANUAL

11NOTE: Although any weight or force up to 100% of the load cellcapacity can be tared , the net capacity of the gage will decrease ifthe tare is more

Seite 4 - A. FORCE FIVE FEATURES

12F. SET-UP INSTRUCTIONSThe FDV Force Gage features a variety of useful options. Theseoptions are selected through the set-up menu. The selection ofma

Seite 5 - Patented Design

13F.1 Accessing the Set-up Menu1. Turn off the FDV2. Press and hold SELECT3. Press POWER4. Release SELECT and POWERThe FDV will display “unit” (Un

Seite 6 - Force Display Module

143. If you wish to change the value, press the SELECT buttonwhen the desired value is displayed; "donE" will appear on thedisplay. To save

Seite 7 - C. SPECIFICATIONS

15period of inactivity (a period during which no buttons arepressed). The period of time can be selected as follows:no FDV does not shut off automatic

Seite 8

16Filtering of peak readings may be set as follows:FP1 Average of 1 sample (No filtering)FP2 Average of 2 samplesFP4 Average of 4 samplesFP8 Average o

Seite 9

17Section F.) and should check other menu settings beforetesting to assure that previously selected values are asdesired. The FDV cannot be shut off i

Seite 10

18G. INTERCHANGING FORCE CELL MODULESThe WAGNER FDV Digital Force Gage presents the user with theunique ability to combine various capacity Force Cell

Seite 11

192. Carefully detach the Force Display Module (front half) from the ForceCell Module (rear half) and set it aside.3. Select the Force Cell Module you

Seite 12

2IMPORTANTREAD THIS BEFORE USING THE FORCE FIVE1. CAUTION: EXCESSIVE OVERLOADS, over 25% above maximumcapacity, or IMPACT LOADING may cause permanent

Seite 13

204. Press SELECT to make a selection; “donE” is displayed.5. To save the option, press SELECT again. The display then returns tonormal operation and

Seite 14

21H. CALIBRATIONTo ensure accuracy in force measurement, the FDV Digital ForceGage should be tested periodically to confirm that it is withintolerance

Seite 15

222. If the FDV is used as an interchangeable system, then auto-calibration is NOT recommended. When the Force Display Moduleis calibrated to one Forc

Seite 16

23H.4 Reversing Auto-CalibrationA gage that has been calibrated in the field using the auto-calibrationfeature is temporarily a dedicated gage, unable

Seite 17

24J. DATA OUTPUTThe Wagner FDV Force Gage offers data output in three formats:RS232, Mitutoyo, and analog. The following sections describethese output

Seite 18

25The RS232 data is transferred in the following format:-XXXXXX YY Peak <CR> <LF>Line FeedCarriage return“Peak” will be transmitted if in

Seite 19

26J.3 Analog OutputThe FDV features a ±1.0 Vdc analog output which is used with analogrecording devices, including strip chart recorders and X-Y plott

Seite 20

27K. PIN ASSIGNMENTSThe 10-pin female output connector of the FDV is located on the leftside of the gage. Three outputs - RS232, Mitutoyo, and Analog

Seite 21

28L. MOUNTING INFORMATIONThe FDV Digital Force Gage may be mounted onto most of thepopular light capacity test stands using the two #8-32 threadedmoun

Seite 22

29M. POWER SUPPLYM.1 PRIMARY SOURCE OF POWERThe best source of power should be determined by the planned use ofgage. For portable usage, battery power

Seite 23

3WAGNER FORCE FIVE™ DIGITAL FORCE GAGEFDV SERIESOPERATION MANUALTABLE OF CONTENTSSection PageA. Force Five Features ...

Seite 24

30AC power for an extended period of time, and the set-up menuhas reverted to default settings. User must reset "LoAd" (seeSection F.) and s

Seite 25

4A. FORCE FIVE FEATURESCONSTRUCTION• Patented modular design - one Force Display Module accommodates up tofive Force Cell Module capacities.• Compac

Seite 26

5FORCE CELL MODULEFive interchangeablemodules available in5, 10, 30, 50 & 100 lbcapacitiesFORCE CELL MODULEFive interchangeablemodules available i

Seite 27 - 10 8 6 4 2

6Select a ForceCell Module (FCM)Attach it to the ForceDisplay Module(FDM)Select the capacityon the keypadTo changecapacityremoveForce CellModule(FCM)S

Seite 28

7C. SPECIFICATIONSWagner FDV Force Gages and Force Cell ModulesFDV 5 FCM 5 5 lb x 0.005 lb 2.5 kg x 0.002 kg 25 N x 0.02 NFDV 10 FCM 10 10 lb x

Seite 29

8D. GENERAL INFORMATIONThe Wagner FDV Digital Force Gage is an economical full functionelectronic force gage. Before using the FDV, take time to becom

Seite 30

9READ THIS BEFORE USING THE FORCE FIVERECOMMENDATIONS1. Warm-up time for the FDV is recommended. After initial power-on,allow 2 - 3 minutes for the el

Kommentare zu diesen Handbüchern

Keine Kommentare