Wagner HIGH PERFORMANCE AIRLESS SPRAYER Bedienungsanleitung Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 33
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
6
WARNING
PREVENTION
HAZARD
Explosion hazard incompatible materials - May cause
property damage or severe injury.
Hazardous vapors - Paints, solvents, insecticides, and
other materials may be harmful if inhaled causing se-
vere nausea, fainting, or poisoning.
General - May cause property damage or severe injury.
DO NOT USE BLEACH.
DO NOT use halogenated hydrocarbon solvents.
Halogenated hydrocarbon solvents such as methylene
chloride and 1,1,1 - Trichlorethane are not compatible
with aluminum and may cause an explosion. If unsure of
a material’s compatibility with aluminum, contact your
coatings supplier.
Use a respirator or mask whenever there is a chance that
vapors may be inhaled. Read all instructions with the
mask to insure that it will provide the necessary protection
against the inhalation of harmful vapors.
Read all instructions and safety precautions before oper-
ating.
Comply with all appropriate local, state and national
codes governing ventilation, fire prevention, and opera-
tion.
The United States Government Safety Standards have
been adopted under Occupational Safety and Health Act.
These standards, particularly the General Standards,
Part 1910 and construction Standard, Part 1926, should
be consulted.
This high pressure airless pump is designed to be used
with authorized parts only. When using this pump with
parts that do not comply with the minimum specifications
and safety devices of the pump manufacturer, the user
assumes all risks and liabilities.
Before each use, check all hoses for cuts, leaks, abrasion
or bulging of cover or damage or movement of couplings.
If any of these conditions exist, replace the hose immedi-
ately. Never repair a paint hose. Replace it with another
grounded hose.
All hoses, swivels, guns, and accessories used with this
unit must be pressure rated at or above 2500 PSI.
DO NOT spray on windy days.